IN OFFICE: TADs IN MODERN ORTHODONTICS.
THE DUAL SYSTEM PHILOSOPHY FOR
RATIONALLY EFFICIENT ORTHODONTICS.
Counting down:
Date:
27-28 March 2026
Price:
1500 EUR
City:
ROME
STUDIO LUZI
ANTONIO GRAMSCI 16
00197 ROMA RM
COURSE TOPICS
TADs IN MODERN ORTHODONTICS
Skeletal anchorage has broadly widened the spectrum of modern orthodontics and increased the clinician’s possible treatment options, both when dealing with growing patients and with adult patients with compromised dentitions. Absolute anchorage can now be planned in any clinical situation aiding the clinician in difficult tasks like space closure, vertical control, intrusion and extrusion of group of teeth, forced eruption of impacted teeth, class II
mechanics and many more. The recent introduction of palatal anchorage with abutment-type miniscrews has broadened even further the horizons of daily clinical practice allowing new protocols for maxillary expansion (MARPE), molar distalization and class III adolescent orthopaedic treatment.
The course will focus on the indications for the use of orthodontic inter-radicular and palatal TADs and the relative biomechanics needed to obtain successful orthodontic tooth movement in a predictable and reliable way. Useful tips and trick will be described in order to facilitate daily clinical work. Daily workflow with the use of fixed appliances, auxiliaries like
intra-oral distalizers, Power bar, Herbst appliance and several others with selected treatment protocols will be fully described and discussed.
THE DUAL SYSTEM PHILOSOPHY FOR
RATIONALLY EFFICIENT ORTHODONTICS.
Self-ligating brackets and the concept of low friction brought on the orthodontic market an
increasing number of innovative treatment techniques and philosophies mainly centered on
the characteristics of the brackets and wires used. Unfortunately, this took away attention
from the the solid principles of a correct and detailed diagnosis, focusing on the concept of a
“simple” and “pre packaged” orthodontics in which the malocclusions adapt to the
mechanics and not viceversa. New generation brackets and archwires should not guide the
treatment decisions but should guarantee to the clinician complete reliability in the
expression of the prescription values and simplify the journey to the treatment objectives.
Low friction is often synonymous of lack of control, especially when using passive-type
brackets, because of the use of undersized archwires in oversized slots, generating difficulties
in torque control, rotation control and finishing of the occlusion. The Dual System Philosophy
was thought for the need to guarantee maximum torque control in the anterior segment
without loosing the benefits of the low friction in the posterior segments. Combining the
feature of the Dual Activation with a bi-dimentional slot size makes it possible to cancel the
weak points of the passive self-ligating bracket allowing simplicity to achieve optimal
results.Self-ligating brackets and the concept of low friction brought on the orthodontic
market an increasing number of innovative treatment techniques and philosophies mainly
centered on the characteristics of the brackets and wires used. Unfortunately, this took away
attention from the the solid principles of a correct and detailed diagnosis, focusing on the
concept of a “simple” and “pre packaged” orthodontics in which the malocclusions adapt to
the mechanics and not viceversa. New generation brackets and archwires should not guide
the treatment decisions but should guarantee to the clinician complete reliability in the
expression of the prescription values and simplify the journey to the treatment objectives.
Low friction is often synonymous of lack of control, especially when using passive-type
brackets, because of the use of undersized archwires in oversized slots, generating difficulties
in torque control, rotation control and finishing of the occlusion. The Dual System Philosophy
was thought for the need to guarantee maximum torque control in the anterior segment
without loosing the benefits of the low friction in the posterior segments. Combining the
feature of the Dual Activation with a bi-dimentional slot size makes it possible to cancel the
weak points of the passive self-ligating bracket allowing simplicity to achieve optimal results.
AGENDA
Soon..
LECTURER

DR CESARE LUZI
Dental degree at the University of Rome “La Sapienza”. Postgraduate education
and Master of Science in Orthodontics at the University of Aarhus, Denmark.
Founder and first President of the European Postgraduate Students
Orthodontic Society (EPSOS). Past President of the Italian Society of
Biomechanics (SIBOS). Past-President of the Italian Association of Specialists in Orthodontics (ASIO) 2018-19.
Active member of SIDO (Italian Society of Orthodontics). President Italian
Academy of Orthodontics 2022. Member of the EOS (European Orthodontic
Society) and WFO (World Federation of Orthodontists). Winner of
the Houston Research Award of the EOS (2006) and of the First Prize Award
for Clinical Research of SIDO (2006).
Winner of the Beni Solow Award of the EOS 2010. Diplomate of the Italian Board of Orthodontics and the European Board of Orthodontics. Visiting
Professor University of Ferrara and University of Rome Cattolica (Italy). Private practice in Rome, limited to orthodontics.
ADDITIONAL INFORMATION
STUDIO LUZI
ANTONIO GRAMSCI 16
00197 ROMA RM
ITALY